CVE-2019-3927

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 anyone can change the administrator and moderator passwords via the iso.3.6.1.4.1.3212.100.3.2.8.1 and iso.3.6.1.4.1.3212.100.3.2.8.2 OIDs. A remote, unauthenticated attacker can use this vulnerability to change the admin or moderator user’s password and gain access to restricted areas on the HTTP interface.
Source: NIST
CVE-2019-3927

CVE-2019-3933

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code simply by requesting /images/browserslide.jpg via HTTP. A remote, unauthenticated attacker can use this vulnerability to watch a slideshow without knowing the access code.
Source: NIST
CVE-2019-3933

CVE-2019-3932

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to authentication bypass due to a hard-coded password in return.tgi. A remote, unauthenticated attacker can use this vulnerability to control external devices via the uart_bridge.
Source: NIST
CVE-2019-3932

CVE-2019-3931

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to argumention injection to the curl binary via crafted HTTP requests to return.cgi. A remote, authenticated attacker can use this vulnerability to upload files to the device and ultimately execute code as root.
Source: NIST
CVE-2019-3931

CVE-2019-3930

The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to a stack buffer overflow in libAwgCgi.so’s PARSERtoCHAR function. A remote, unauthenticated attacker can use this vulnerability to execute arbitrary code as root via a crafted request to the return.cgi endpoint.
Source: NIST
CVE-2019-3930

CVE-2019-3928

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allow any user to obtain the presentation passcode via the iso.3.6.1.4.1.3212.100.3.2.7.4 OIDs. A remote, unauthenticated attacker can use this vulnerability to access a restricted presentation or to become the presenter.
Source: NIST
CVE-2019-3928

CVE-2019-3926

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to command injection via SNMP OID iso.3.6.1.4.1.3212.100.3.2.14.1. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.
Source: NIST
CVE-2019-3926

CVE-2019-3925

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to command injection via SNMP OID iso.3.6.1.4.1.3212.100.3.2.9.3. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.
Source: NIST
CVE-2019-3925

CVE-2019-3929

The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.
Source: NIST
CVE-2019-3929